- Trang chủ /
- vật tư công nghiệp /
- Test, Measure & Inspect /
- Substance Analysis Instrumentation /
- Electrodes /
- Total Ionic Strength Adjustment Buffer (TISAB...
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
VND 4977180
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from Hoa Kỳ
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
What Stands Out
Thông tin chi tiết sản phẩm
- Ready-to-use solutions provide savings in raw materials, labor and waste disposal
- Tight specifications for the most accurate results
- Minimal lot-to-lot variation improves reproducibility
- Certified traceable to NIST for regulatory compliance
| Item Form | Liquid |
| Volume | 4 liters |
| Brand Name | Ricca Chemical |
| Unit Count | 1 Count |
| Manufacturer | Ricca Chemical Company |
| Part Number | 8670-1 |
| Brand | Ricca-Chemical |
| Item Volume | 4 liters |
| Item Weight | 1.5 lbs (680 grams) |
Who Should Buy?
-
Laboratory Technicians
Essential for technicians conducting fluoride analysis using ion selective electrodes in various laboratory environments.
-
Environmental Scientists
Ideal for scientists assessing water quality and fluoride concentrations in environmental samples and field studies.
-
Academic Researchers
Beneficial for researchers in academia performing experiments related to fluoride chemistry and ion analysis.
-
Home Users
Not suitable for casual users without specialized knowledge or equipment for fluoride testing at home.
MÔ TẢ SẢN PHẨM
Hỏi Đáp dành cho Khách hàng
-
câu hỏi:
What is TISAB II and how is it used in fluoride analysis?
trả lời: Total Ionic Strength Adjustment Buffer TISAB II is a specially formulated solution designed to stabilize the ionic strength and pH during fluoride analysis. It ensures the accuracy of ion selective electrodes by preventing interference from other ionic species in the sample. For instance, in environmental testing of water for fluoride levels, using TISAB II allows for precise measurements that align with regulatory standards, making it essential for laboratories dealing with water quality assessment. -
câu hỏi:
What does CDTA in TISAB II stand for?
trả lời: CDTA stands for Cyclohexyl-2,6-diethyl-2,4-pyrimidinediamine, which is included in TISAB II to combat interference from metal ions. This complexing agent effectively binds to metal cations, preventing them from distorting fluoride measurements. In practical scenarios, laboratories that face the challenge of metallic contaminants during fluoride testing can rely on TISAB II with CDTA to achieve more reliable results. -
câu hỏi:
How should TISAB II be prepared and stored for optimal use?
trả lời: TISAB II should be stored in a cool, dry place and kept tightly sealed to prevent contamination. It is important to follow specific preparation guidelines provided by the manufacturer for achieving the ideal concentration before use. Laboratories performing regular tests can benefit from maintaining a fresh supply of TISAB II, as old solutions may deteriorate, affecting the accuracy of fluoride analysis. -
câu hỏi:
Can TISAB II be used in different types of water analysis?
trả lời: Yes, TISAB II is versatile and can be used in various types of water analysis, including groundwater, drinking water, and wastewater. Its formulation is designed to accommodate the unique ionic challenges posed by different water sources. For example, treatment plants analyzing fluoride levels in both raw inflow and treated effluent can utilize TISAB II to ensure consistent and precise fluoride readings across samples. -
câu hỏi:
Is TISAB II compatible with all ion selective electrodes?
trả lời: TISAB II is compatible with most ion selective electrodes designed for fluoride analysis, as it enhances their performance by providing a controlled ionic environment. However, it's essential to check the specifications of your particular electrode to confirm compatibility. Laboratories equipped with multiple electrode systems can leverage TISAB II for interchangeable use, enhancing their operational efficiency. -
câu hỏi:
What are the advantages of using TISAB II over traditional buffers?
trả lời: TISAB II offers enhanced ionic strength adjustment and minimizes interference from other ions, unlike many traditional buffers. It helps to stabilize the pH and ionic environment crucial for accurate fluoride ion readings. Laboratories focusing on quality control and environmental monitoring can gain a significant edge by using TISAB II, as it ensures that they meet the necessary analytical standards. -
câu hỏi:
How is TISAB II disposed of after use?
trả lời: The disposal of TISAB II should be conducted in compliance with local regulations regarding chemical waste disposal. It's essential to check safety data sheets (SDS) provided by manufacturers for specific disposal guidelines. Laboratories can incorporate proper disposal methods in their standard operating procedures to ensure environmental responsibility while handling chemical waste. -
câu hỏi:
What precautions should be taken when handling TISAB II?
trả lời: When handling TISAB II, it is advisable to use gloves and safety goggles to prevent skin and eye irritation. Always work in a well-ventilated area to minimize inhalation of vapors. Research and laboratory personnel who frequently use TISAB II in analyses should undergo proper training on handling hazardous materials to ensure safety and compliance with best practices. -
câu hỏi:
Is TISAB II suitable for field testing applications?
trả lời: While TISAB II is primarily used in laboratory settings, it can be employed for field testing when immediate results are necessary. Its compact and easily transportable nature allows field researchers to conduct fluoride analysis on-site effectively. For environmental assessments where swift decision-making is crucial, TISAB II serves as an ideal solution to complement portable ion selective electrodes. -
câu hỏi:
Where can I buy Total Ionic Strength Adjustment Buffer TISAB II, with CDTA for Fluoride Analysis Using Ion Selective Electrodes in Vietnam?
trả lời: You can buy Total Ionic Strength Adjustment Buffer TISAB II with CDTA for Fluoride Analysis Using Ion Selective Electrodes on Ubuy. This platform offers a variety of laboratory supplies, making it easier for you to find the specific buffers needed for accurate fluoride testing. Ubuy provides convenient options for exploring and acquiring necessary laboratory materials for your analysis needs.
Ricca Chemical Electrodes Editorial Review
Customer Reviews & Ratings
-
5 sao
100%
-
4 sao
0%
-
3 sao
0%
-
2 sao
0%
-
1 sao
0%
Đánh giá sản phẩm này
Chia sẻ suy nghĩ của bạn với các khách hàng khác
Platform Trust & Buyer Confidence
“Excellent quality and original too,when ubuy send original things I will appreciate that ,I very satisfied thank you”
“The order and delivery progress was communicated very well. Package arrived within the estimated time. Products arrived as expected in good condition.”
“Good supply of products. Safe payment methods, and shipment worldwide! Genuine products.”
“Was my first time buying a product from Ubuy, but I found it so helpful. This is reliable. Gonna place a new order!”
“Ubuy is a great online platform to buy stuff. Reliable, fast delivery time and great value for money. I've been using Ubuy online shopping platform for three years now and will continue to do so.”
Product Price History
Thông tin quan trọng
- Hạn chế: Đối với các sản phẩm được vận chuyển quốc tế, xin lưu ý rằng bất kỳ chính sách bảo hành nào của nhà sản xuất có thể không còn hiệu lực; các tùy chọn dịch vụ của nhà sản xuất có thể không khả dụng; hướng dẫn sử dụng sản phẩm, hướng dẫn và cảnh báo an toàn có thể không có bằng ngôn ngữ của quốc gia đến; các sản phẩm (và các tài liệu đi kèm) có thể không được thiết kế theo các tiêu chuẩn, thông số kỹ thuật và các yêu cầu ghi nhãn của quốc gia đến; và các sản phẩm có thể không phù hợp với điện áp của quốc gia đến cũng như các tiêu chuẩn khác về điện (cần phái sử dụng đầu nối hoặc bộ chuyển đổi nếu thích hợp). Người nhận có trách nhiệm đảm bảo rằng sản phẩm có thể được nhập khẩu hợp pháp đến quốc gia đến. Khi đặt hàng từ Ubuy hoặc các chi nhánh của Ubuy, người nhận là nhà nhập khẩu trong hồ sơ, đồng thời phải tuân thủ tất cả các luật cũng như quy định của quốc gia đến.
- Không phải tất cả các sản phẩm được liệt kê trên Ubuy đều được rao bán, vì Ubuy là một công cụ tìm kiếm toàn cầu. Sản phẩm phải tuân theo các quy định về xuất khẩu/thương mại.
VND 4977180
Đặt hàng ngay bây giờ và nhận hàng vào khoảng Thứ Sáu, Tháng Tám 28
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
PCI DSS compliant and ISO 27001:2022 certified, with encrypted payments and full buyer protection on every order.
Các tính năng và lợi ích
- Manufactured with ACS Reagent grade raw materials.
- Designed specifically for Fluoride Analysis using Ion Selective Electrodes.
- Lot numbered and expiration dated for quality assurance.
- Tight specifications ensure the most accurate results.
- Minimal lot-to-lot variation improves reproducibility.
- Certified traceable to NIST for regulatory compliance.
Ubuy Assurance
Experience worry-free shopping with 100% original products, PCI DSS-compliant payment security, ISO 27001-certified data protection, the fastest cross-border delivery, free returns *, and secure packaging on every order.